Logo Teseq
formerly Schaffner Test Systems
WORLDWIDE
Choose your country:

Coupling / decoupling networks (CDN)

CDN_selection_chart
CDN selection chart
CDN selection chart (3943.91 KB)

CDN M Type

Coupling decoupling network CDN M116
  • Designed for IEC/EN 61000-4-6
  • For PE line application
  • 4 mm banana sockets
CDN M116 e (748.39 KB)
Coupling decoupling network CDN M016, M210B, M216, M310B, M316, M316B
  • Designed for IEC/EN 61000-4-6
  • CDN M016 switchable M2 or M3
  • Types with 4 mm banana sockets
  • Performance up to 230 MHz
CDN M016 216 316 e (1404.15 KB)
Coupling decoupling network CDN M416, M416-3LN, M516
  • Designed for IEC/EN 61000-4-6
  • 4 mm banana sockets
  • CDN M516 AE port supplied with CEE socket
CDN M416 516 e (970.82 KB)
Coupling decoupling network CDN M232, M332, M432, M432-3LN, M532
  • Designed for IEC/EN 61000-4-6
  • Mains application up to 32 A
  • 4 mm banana sockets
  • Frequency range 150 kHz to 230 MHz
CDN M232 332 432 532 e (681.1 KB)

CDN AF Type

Coupling decoupling network CDN A201, A301, A401
  • Used for unscreened, unbalanced lines, carrying low current
  • Designed for IEC/EN 61000-4-6
  • 4 mm banana sockets
  • Performance up to 230 MHz
CDN A201 301 401 e (954.72 KB)
Coupling decoupling network CDN A800, A150
  • Used for unscreened, unbalanced lines, carrying low current
  • Up to 15 lines
  • Designed for IEC/EN 61000-4-6
  • D-Sub sockets
  • Performance up to 230 MHz
CDN A800 150 e (865.3 KB)

CDN S Type

Coupling decoupling network CDN S150, S200, S250, S400, S900
  • Used for screened cables
  • Up to 25 lines
  • Designed for IEC/EN 61000-4-6
  • Types with D-Sub sockets
  • Performance up to 230 MHz
CDN S150 200 250 400 900 e (1115.69 KB)
Coupling decoupling network CDN S501, S751
  • Used for coaxial cables
  • Designed for IEC/EN 61000-4-6
  • BNC sockets
CDN S501 751 e (846.89 KB)
Coupling decoupling network CDN ST08A
  • For testing screened, balanced lines for telecommunication ports on ITE equipment.
  • For use with screened RJ45 connections
  • Up to 8 lines/ 4 pairs
  • Designed for IEC/EN 61000-4-6
  • Meets the requirements of CISPR 22, Ed.5.0, Ed.5.2 and Ed.6.0
CDN ST08A e (775.75 KB)

CDN USB Type

Coupling decoupling network CDN USB/c, USB/p
  • Designed for IEC/EN 61000-4-6
  • USB/c for test central devises
  • USB/p for test periferal devises
CDN USB e (274.66 KB)

CDN CAN BUS Type

CDNs for CAN BUS application
  • Designed for IEC/EN 61000-4-6
  • CAN BUS application
  • Two different types for four or five lines
  • D-Sub-9-sockets
CDN CAN e (240.64 KB)

CDN T Type

CDNs for unscreened balanced pairs, CDN T210A...T246AS, CDN T411A...T4AS
  • CDN T2xxA for one unscreened balanced pair
  • CDN T4xxA for two unscreened balanced pairs
  • Designed for IEC/EN 61000-4-6
  • RJ11 and RJ45 sockets with different
  • pin-arangements as required by the application
CDN T2xx T4xx e (734.78 KB)
CDNs for unscreened balanced pairs, CDN T8
  • For use with one, two, three, or four unscreened balanced pairs
  • Designed for IEC/EN 61000-4-6 and CISPR 35 broadband impulsive noise tests
  • 1000BaseT and PoE application
  • RJ11 and RJ45 sockets
CDN T8 e (311.94 KB)

CDN 10 kHz to 80 MHz

Coupling decoupling network M1 for 10 KHz to 80 MHz
  • Designed for IEC/EN 61000-4-6 with extended range form 10 kHz to 80 MHz
  • For PE line application
  • 4 mm banana sockets
CDN M1 10 e (230.84 KB)
Coupling decoupling network M2 and M3 for 10 kHz to 80 MHz
  • Designed for IEC/EN 61000-4-6 with extended range form 10 kHz to 80 MHz
  • For M2 and M3 application
  • 4 mm banana sockets
CDN M216 10 316 10 e (307.38 KB)
Coupling decoupling network S9 for 10 kHz to 80 MHz
  • Used for screened cables
  • Up to 9 lines
  • Designed for IEC/EN 61000-4-6 with extended range form 10 kHz to 80 MHz
  • Type with D-Sub sockets
CDN S900 10 e (225.7 KB)
Coupling decoupling network ST08 for 10 kHz to 80 MHz
  • For testing screened, balanced lines for telecommunication ports on ITE
  • equipment.
  • For use with screened RJ45 connections
  • Up to 8 lines/ 4 pairs
  • Designed for IEC/EN 61000-4-6 with extended range form 10 kHz to 80 MHz
CDN ST08 10 e (227.76 KB)
Coupling decoupling network CDN A201, A301, A401 for 10 kHz to 80 MHz
  • Used for unscreened, unbalanced lines, carrying low current
  • Designed for IEC/EN 61000-4-6 with extended range form 10 kHz to 80 MHz
  • 4 mm banana sockets
CDN A201 301 401 10 e (322 KB)

CDN CISPR 15

CDNE M210 Coupling decoupling network for emission measurement
  • Frequency range 30 to 300 MHz
  • Version M2 with 10 A
  • Conform with CISPR 15 and JT_F_A_21_Requirement CDNE_v4
CDNE M210 e (175.79 KB)
CDNE M310 Coupling decoupling network for emission measurement
  • Frequency range 30 to 300 MHz
  • Version M3 with 10 A
  • Conform with CISPR 15 and JT_F_A_21_Requirement CDNE_v4
CDNE M310 e (170.93 KB)
Coupling decoupling network for CISPR 15 measurements
  • Designed for IEC/EN 61000-4-6 and CISPR 15/ EN 55015
  • Types with 4 mm banana sockets or sub-D connectors
  • Performance up to 300 MHz
CDN CISPR 15 e (213.49 KB)

CDN/ISN CISPR 22

Impedance stabilization network ISN T2A
  • For use with one unshielded balanced pair
  • CISPR 22, Ed.5.2, 2006 and EN 55022 Sept. 2006 (IEC/CISPR 22: 2005 modified) for Cat.3 and Cat.5
  • Changeable pin-arrangements with RJ11 and RJ45
  • Can be used as CDN for IEC 61000-4-6 immunity tests
ISN T2 e (251.11 KB)
Impedance stabilization network ISN T4A
  • For use with one or two unshielded balanced pairs
  • CISPR 22, Ed.5.2, 2006 and EN 55022 Sept. 2006 (IEC/CISPR 22: 2005 modified) for Cat.3 and Cat.5
  • Changeable pin-arrangements with RJ11 and RJ45
  • Can be used as CDN for IEC 61000-4-6 immunity tests
ISN T4 e (341.04 KB)
Impedance stabilization network ISN T8
  • For use with one, two, three, or four unscreened balanced pairs
  • CISPR 22, Ed.5.2, 2006 and EN 55022 Sept. 2006 (IEC/CISPR 22: 2005 modified) for Cat.3 and Cat.5
  • 1000 BaseT and PoE application
  • Changeable pin-arrangements with RJ11 and RJ45
ISN T8 e (288.51 KB)
Impedance stabilization network ISN T8-Cat6
  • ISN T8 for cable category 6 (LCL 75/60 dB) and RJ45 connection
  • For use with one, two, three, or four unscreened balanced pairs CISPR 22, Ed.5.2, 2006 and EN 55022 Sept. 2006 (IEC/CISPR 22: 2005 modified) for Cat.6
  • 1000BaseT and PoE application
  • Transmission bandwidth 250 MHz
  • Can be used as CDN for IEC 61000-4-6 immunity tests
ISN T8-Cat6 e (560.73 KB)
Impedance stabilization network ISN ST08
  • For use with screened RJ45 connections
  • Up to 8 lines/ 4 pairs
  • Meets the requirements of CISPR 22, Ed.5.2
  • Design given in figure D.11 of CISPR 22, Ed.5.2
  • Can be used as CDN for IEC 61000-4-6 immunity tests
ISN ST08 e (195.98 KB)
Impedance stabilization network ISN S501
  • For use with coaxial lines
  • BNC connectors
  • Meets the requirements of CISPR 22, Ed.5.2
  • Design given in figure D.9 of CISPR 22, Ed.5.2
  • Can be used as CDN for IEC 61000-4-6 immunity tests
ISN S501 e (198.28 KB)
CAS ISN, calibration kit for ISN T
  • Meets CISPR 22 ed. 5.2 and CISPR 16-1-2
  • Optional extensible for measurements on ISN T2 and ISN T8-Cat6
  • Measurements for common mode impedance, phase angle, voltage division factor, decoupling attenuation (isolation) and longitudinal conversion loss (LCL)
CAS ISN e (713.3 KB)
CAS ISN-EXT-TRA, extension for transmission and crosstalk
  • Extension for CAS ISN
  • Measurements for transmission and crosstalk
  • Suitable for cat.6 (250 MHz)
CAS ISN EXT TRA e (308.13 KB)
Magnetic fixture for ISN T2A, ISN T4A, ISN T8, ISN T8-Cat6 or CDN T8
  • Improvement of the ISN earth connection to steel surfaces
  • Allows vertical positioning of the ISN (chamber wall)
  • Easy positioning of the ISN in the setup
  • Ruggedly designed
FIX ISN e (133.27 KB)
ISN for power line telecommunication (PLT) ISN PLT
  • For use with Type 1 & 2 PLT devices
  • Switchable LCL
  • Conform with CISPR/I/301/CD
  • Supplied with Coupling Unit
ISN PLT e (554.79 KB)
ISN for power line telecommunication (PLT) ISN PLT-A
  • For asymmetric disturbance measurements on PLT devices
  • Frequency range 1.6 to 30 MHz
  • LCL >55 dB
  • Conform with EN 50561-1
  • Supplied with Coupling Unit
ISN PLT-A e (408.47 KB)

CDN CISPR 35

CDNs for unscreened balanced pairs, CDN T8
  • For use with one, two, three, or four unscreened balanced pairs
  • Designed for IEC/EN 61000-4-6 and CISPR 35 broadband impulsive noise tests
  • 1000BaseT and PoE application
  • RJ11 and RJ45 sockets
CDN T8 e (311.94 KB)
Direct entry:
Next exhibition
February 7 - 9, 2012:
EMV 2012, Düsseldorf, Germany ...
Links
© 2012 Teseq | Impressum | Disclaimer | Sitemap | Feb 8 2012 3:16 AM